Anechoic Military Test chamber designed to meet DEF STAN 59-411

DEF STAN 59-411 Military Test Chamber

Global EMC’s DEF STAN 59-411 Military test chamber facility has been specifically designed for the varied and heavy-duty testing required by the military. DEF STAN (UK Defence Standardisation) 59-411 is the equivalent of, yet more stringent military standards of the US related MIL-STAN.

The chamber is constructed using a self-standing steel structure and modular steel shield and is used for the EMC testing and inspection of critical components of defence qualification programs.

Contact us for more Information
Anechoic Military Test chamber designed to meet DEF STAN 59-411

Choose This Test Chamber For

Drone icon for Military DEF STAN 59-411

RTCA DO-160

RTCA DO-160 (aerospace) test procedures; a standard for the environmental testing of avionics hardware

Global EMC Security for DEF STAN 59-411

Shield Attenuation

Fully compliant emissions testing to EN 50147-1, a BSI standard for validating shielding effectiveness.

tank icon DEF STAN 59-411

Military Testing

Built to MIL-STD-461 standards for the control of electromagnetic interference (EMI).

This Product Features

Due to the varied dimensions and requirements of the equipment under test (EUT), all DEF STAN 59-411 chambers are designed and manufactured to exact requirements.

 

Testing facility for performing compliant tests to DEF STAN 59-411, MIL-STD-461 and RTCA DO-160. The chamber can be designed to test small electronic equipment to very large military vehicles. Communication and electrical equipment, armaments, aircraft equipment and vehicles are all examples of what can be tested.

Global EMC’s DEF STAN shielded test facility uses GF 102 ferrite tile and high-performance pyramidal Hybrid Absorbers.

Anechoic Chamber for Military use, designed to meet DEF STAN 59-411

DEF STAN 59-411 Military EMC Test Facility

DEF STAN 59-411

A dedicated military EMC test facility for the measurement and analysis of conducted emissions, susceptibility, radiated emissions, radiated emission, radiated susceptibility and electrostatic discharge.

Military

Specifically relating to UK defence standardisations.

EMC

Electromagnetic compatibility or EMC testing gives the manufacturer of a product the ability to demonstrate the ability of their product.

Test Facility

An EMI/RFI shielded room, using a Faraday cage principle. This is to stop unwanted signals from the ambient environment entering the chamber and causing interference whilst tests are being performed.

High-Performance Anechoic Lining

Ferrite Tiles & Absorbers – The walls and ceiling of the test chamber are precisely lined with the latest generation gapless Hybrid Pyramid absorbers and Ferrite tiles. The Pyramidal absorbers are precisely doped to ensure a smooth transition between the high performance of the Ferrite tiles at lower frequencies to the Pyramidal absorbers in higher frequencies. The “plug-in” base system of the absorbers means that individual absorber cones can be replaced if accidentally damaged during operation of the test chamber. This reduces the cost of repairs and time taken for the test chamber to become fully operational again.

Pyramidal Absorbers


Height

450mm

Part Number

RLT-450

Minimum Dimensions


Length

Custom Size

Width

Custom Size

Height

Custom Size

Shielding Effectiveness tested to EN 50147-1

Every Global EMC anechoic chamber is provided with a Faraday cage shield. The shielded enclosure provides both an area free from external ambient signals but also protection during Immunity testing for personnel working outside the chamber.

The measure of shielding performance is conventionally known as “shielding effectiveness”. 100dB in plane and microwave frequencies is generally regarded by most standards as a very high level of shielding suitable for scientific use.

Global EMC offer two levels of shielding Standard and Extended Performance. Standard performance is suitable for most shielding requirements and is typically seen in commercial testing situations. Extended Performance is usually used in high-performance Military applications along with certain high frequency needs.

DEF STAN 59-411 Military Test Chamber

Anechoic Military Test chamber designed to meet DEF STAN 59-411
Contact us for more Information
Key Features

Anechoic performance in accordance to DEF STAN 59-411.

Shield effectiveness to EN 50147-1.

1m measuring distance.

Designed and manufactured to the highest standards in Great Britain.

Bespoke solution upon request. Test facility can be configured to your exact requirements.

Industry-leading low maintenance shielded door with copper-beryllium knife-edge seals.

Moulded polystyrene pyramidal Hybrid Absorbers to all walls, ceiling and partial floor covering. (Absorber coverage as far as physically possible).

Latest technology high-performance GF 102 ferrite tiles to all walls, ceiling and floors.

Specialist filters are available.

Conductive test bench grounded to the chamber to requirements.
Full Specification

External DimensionsTo customer requirements*.

Shielded Pedestrian Door (Clear Opening)1000mm (W) x 2000mm (H)*

Steel StructureSelf-supporting structure to industry standards.

ShieldModular 2mm steel “pan” shield.

Honeycomb Vents4 x 300mm (W) x 300mm (H) (static air).

Penetration Panel Connectors2 x Precision N type, & 2 x Fibre.

Additional Options Include:
Mast, Fire detection, Vehicle Sliding Doors, Air conditioning (HVAC), CCTV, Test benches, Vehicle fume extraction, Whitecaps to absorbers, Lighting, Power, Turntable, Heavy floor loadings, DC Sockets, Filters & Audio communication.
*All dimensions can be altered upon request (subject to compatibility).