CISPR 25 Automotive Vehicle Test Facility


Global EMC’s CISPR12/25-V and CISPR12/25-10m-V automotive test facility has been specifically designed for automotive testing to meet the requirements of compliant EN55025/CISPR 25 testing.

The chamber is also compliant for immunity tests to ISO 11452-2 and is constructed using a self-standing steel structure and modular steel shield.

Contact us for more Information

Choose This Test Chamber For

Performing compliant radiated emissions with EN55025/CISPR 25 and complaint immunity testing to ISO 11452-2. The chamber is used for testing electronic sub-assemblies of receivers mounted on-board vehicles.

Global EMC - Military Testing Capabilities

Military Testing

Built to MIL-STD-461 standards for the control of electromagnetic interference (EMI).

RTCA DO160 - Global EMC

RTCA DO160

RTCA DO-160 test procedures; a standard for the environmental testing of avionics hardware

Shield Effectiveness - Global EMC

Fully Compliant

Fully compliant emissions testing to CISPR 16-1-4 and compliant immunity testing to EN6100-4-3.

5m Compliant Semi-Anchoic EMC Test Chamber - Global EMC

Vehicle Testing

Compliant with: CISPR11/EN 55012, CISPR25/EN 55025 and CISPR32/EN 55032

This Product Features


This is test facility is complimented with high-performance pyramidal hybrid absorbers and ferrite tiles to walls and ceiling as required to make a semi-anechoic chamber. The CISPR12/25 Vehicle chambers are designed and manufactured to exact requirements but as standard come in two sizes.

CISPR12/25-V is for smaller vehicles using a 3-meter measuring distance. CISPR12/25-10m-V is large enough to fit most vehicle sizes and uses a 10-meter measuring distance.

CISPR Automotive Vehicle Test Chambers

CISPR 25


CISPR 25 ISO 11452-1 covers immunity testing for the components within vehicles, boats and internal combustion engines, radio disturbance characteristics and on-board receivers.

Automotive Vehicle


Relating to or concerned with motor vehicles – Specifically involving a combustion engine.

EMC


Electromagnetic compatibility or EMC testing gives the manufacturer of a product the ability to demonstrate the ability of their product.

Test Facility


The external construction is a shielded room, using a Faraday cage principle. This is to stop unwanted signals from the external environment entering the chamber and causing interference whilst tests are being performed.

High-Performance Anechoic Lining

Ferrite Tiles & Absorbers – The walls and ceiling of the test chamber are precisely lined with the latest generation absorbers and Ferrite tiles. The Pyramidal absorbers are precisely doped to ensure a smooth transition between the high performance of the Ferrite tiles at lower frequencies to the Pyramidal absorbers in higher frequencies.

Frequency Test Range


Low

70MHz

High

2.5GHz

Minimum Dimensions (CISPR12/25 25-V)


Length

11.50m

Width

7.00m

Height

4.50m

Minimum Dimensions (CISPR12/25 10-V)


Length

26.50m

Width

15.00m

Height

9.50m

Shielding Effectiveness tested to EN 50147-1

Every Global EMC anechoic chamber is provided with a Faraday cage shield. The shielded enclosure provides both an area free from external ambient signals but also protection during Immunity testing for personnel working outside the chamber.

The measure of shielding performance is conventionally known as “shielding effectiveness”. 100dB in plane and microwave frequencies is generally regarded by most standards as a very high level of shielding suitable for scientific use.

Global EMC offer two levels of shielding Standard and Extended Performance. Standard performance is suitable for most shielding requirements and is typically seen in commercial testing situations. Extended Performance is usually used in high-performance Military applications along with certain high frequency needs.

01


Anechoic performance for CISPR 25 is greater than – 6dB from 70 MHz to 2.5 GHz at normal incidence.

02


Shield effectiveness to EN 50147-1.

03


3m or 10m measuring distance.

04


Designed and manufactured to the highest standards in Great Britain.

05


Bespoke solution upon request. Test facility can be configured to your exact requirements.

06


EUT Conductive test table with a reflective metal ground plane.

07


Industry-leading low maintenance shielded door with copper-beryllium knife-edge seals.

08


Lighting, power filter, penetration and static ventilation panels all as standard.

09


Latest technology high-performance GF 102 ferrite tiles to all walls, ceiling and partial floor covering.

10


Moulded polystyrene pyramidal Hybrid Absorbers to all walls, ceiling and partial floor covering. (Absorber coverage as far as physically possible).

11


Can be designed for compliant EMC on request.

External Dimensions


11.5m (L) x 7m (W) x 4.5m (H)*.

Shielded Pedestrian Door (Clear Opening)


1000mm (W) x 2000mm (H)*

Vehicle Entry Door


2500mm (W) x 2500mm (H)*.

Shield


Modular 2mm steel “pan” shield.

EUT Conductive Test Table (C/W Grounding).


2m (L) x 1m (W) x 0.9 (H)*.

Floor Loading (Standard)


1 Ton/M²*.

Filters


1 x 32A 230V Single phase (2 line).

Penetration Panel Connectors


2 x Precision N type, & 2 x Fibre.

Honeycomb Vents


2 x 600mm (W) x 600mm (H) (static air).

Access Ramp


Included.

Lighting


4 x LED Lighting 1 x Emergency light.

Power Distribution


4 x 230V AC DSSO Sockets.

Vehicle Fume Extraction System


Included.

Aspirating Fire Detection System


Included.

Warranty


3 year as standard.

Additional Options Include:
Mast, Fire detection, DC power sockets, Air conditioning, CCTV, DC Filters, white end caps to absorbers, Filters & Audio communication.
*All dimensions and quantities can be altered upon request (subject to compatibility).

External Dimensions


26m (L) x 15m (W) x 9.5m (H)*.

Shielded Pedestrian Door (Clear Opening)


1000mm (W) x 2000mm (H)*

Vehicle Entry Door


2500mm (W) x 2500mm (H)*.

Shield


Modular 2mm steel “pan” shield.

EUT Conductive Test Table (C/W Grounding).


2m (L) x 1m (W) x 0.9 (H)*.

Floor Loading (Standard)


1 Ton/M²*.

Filters


1 x 32A 230V Single phase (2 line).

Penetration Panel Connectors


2 x Precision N type, & 2 x Fibre.

Honeycomb Vents


2 x 600mm (W) x 600mm (H) (static air).

Access Ramp


Included.

Lighting


10 x LED Lighting 1 x Emergency light.

Power Distribution


8 x 230V AC DSSO Sockets.

Vehicle Fume Extraction System


Included.

Aspirating Fire Detection System


Included.

Warranty


3 year as standard.

Additional Options Include:
Mast, Fire detection, DC power sockets, Air conditioning, CCTV, DC Filters, white end caps to absorbers, Filters & Audio communication.

*All dimensions and quantities can be altered upon request (subject to compatibility).

01


EN55025 / CISPR 25.

02


EN55012 / CISPR 12.

03


EN55016 / CISPR 16-1-4 (CISPR12/25-10m-V).

04


MIL-STD-461, DEF STAN 59-411, ISO 11452-2.

05


EN6100-4-3, EN 50147-1.