TempestShielded Rooms


Global EMC’s TEMPEST room works on the Faraday cage principle of a 6 sided metal enclosure, providing a controlled environment, free from electromagnetic interference (EMI) and ambient RF signals from entering or exiting the room.
Designed around TEMPEST and NATO SDIP-29 the shielded room provides a suitable location for police, defence/military or embassies to protect sensitive information.

Each installation is independently tested and certified by a UKAS approved ISO17025 test body.
A turnkey solution is provided by Global EMC to specify, design, manufacture, install and provide final certification and testing of the complete project. High-quality internal finishes are also provided including lighting, power, data and HVAC to make the Forensic room durable, practical and comfortable.

Learn More
Tempest Shielded Room - Global EMC

Choose This Test Chamber For


Full level A SDIP-27 NATO TEMPEST application standards. This is the strictest standard for devices that will be operated in NATO Zone 0 environments.

NATO Standard - Global EMC

NATO Standard

NATO SDIP-29 and SDIP-27 TEMPEST standards.

Global EMC - Military Testing Capabilities

Military Use

For secure meeting and conference rooms providing shielding from 1 kHz to 10 GHz.

Anti-Bugging Protection - Global EMC

Anti-Bugging

To prevent mobile phones and recording devices from streaming audio from inside the room.

Quiet Room - Global EMC

Quiet Room

For interrogation of mobile phones and other communication devices.

Simplicity in Flexibility


Designed and individually manufactured by Global EMC enables every installation to be bespoke and uniquely shaped to exact requirements and specifications.

The shield is constructed from pre-fabricated modular panels, each panel is fitted together on-site to form a completely “sealed” six-sided enclosure. The flexible modular system enables almost any size and shape of the room to be created. Installed as a self-supporting free standing room or architectural shielding fitted onto an existing room, the enclosures can be sized to fit the host building and maximise the usable space.

The installation has no hot works or welding and can easily be disassembled and re-located. The external façade is finished with a premium quality finish to match the client’s company colours or simply complement the surrounding space.

Learn More

Finishing Touches


Upon the completion of the shield, numerous options are available to tailor the shielded room to exact requirements. Rooms can be left as a bare shield for an industrial and durable finish or lined with plasterboard, melamine board or cleanroom finishes.

Office-style interiors are available including vinyl, anti-static or carpeted floors, dimmable lighting, mains power, data and furniture. For telecommunications or IT networks, raised false flooring can be provided, server cabinets and air conditioning.

To ensure the integrity of the shield, all penetrations are accounted for as required. Fire alarm, air conditioning, cameras, compressed air are just some of the limitless possibilities that can be integrated into the shield.

Learn More

01


Ultra-high shielding performance as standard.

02


Shielding effectiveness to EN 50147-1 and IEEE299.

03


Standard shield performance of 60dB @ 10 MHz, 100dB @ 200 MHz, 100dB @ 1-18 GHz.

04


Shield performance can be extended to 1 kHz – 86 GHz upon request.

05


Designed and manufactured to the highest standards in Great Britain.

06


Bespoke solution upon request. The enclosure can be configured to your exact requirements.

07


Industry-leading low maintenance shielded door with copper-beryllium knife-edge seals.

08


Designs created in Solidworks® and AutoCAD to ensure ideal configuration and coordination.

09


All materials are shipped in component form and fit through a standard doorway for ease of installation.

10


Mains distribution and LED lighting as required.

11


Internal finish to exact requirements.

External Dimensions


To customer requirements*.

Shielded Pedestrian Door (Clear Opening)


1000mm (W) x 2000mm (H)*

Steel Structure


Self-supporting structure to industry standards.

Shield


Modular 2mm steel “pan” shield.

Honeycomb Vents


4 x 300mm (W) x 300mm (H) (static air).

Penetration Panel Connectors


2 x Precision N type, & 2 x Fibre.

Warranty


1 year as standard.

Additional Options Include:
Mast, Fire detection, Vehicle Sliding Doors, Air conditioning (HVAC), CCTV, Test benches, Vehicle fume extraction, Whitecaps to absorbers, Lighting, Power, Turntable, Heavy floor loadings, DC Sockets, Filters & Audio communication.
*All dimensions can be altered upon request (subject to compatibility).

01


Tempest (secure speech), Government institutions, Secure data centres / Server rooms, Anti-bugging or to prevent mobile communications equipment being used, SDIP-27 NATO, TEMPEST Standards.

02


NATO Standard, Military applications, Commercial security, Quiet rooms for phone and other communication device interrogation, EN50147-1.

03


RTCA DO-160 Aerospace.